[REQ-END-110] Configure User Rights: Force shutdown from a remote system
Target Scope
- Applicable Systems: Tier 2 client workstations and member servers. (For Tier 0 Privileged Access Workstations, refer to tightened baseline REQ-PAW-103). (For Domain Controllers, refer to REQ-DC-123).
- Operating Systems: Windows 10 Enterprise/Professional (1809 and above), Windows 11 Enterprise/Pro, Windows Server 2016, 2019, 2022, and 2025.
Implementation Details
- Priority: Medium
- GPO Path / Registry Location:
- Policy Display Name:
Force shutdown from a remote system - Privilege Constant:
SeRemoteShutdownPrivilege - GPO Path:
Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\User Rights Assignment\Force shutdown from a remote system - Registry Location: Stored inside local security database under privilege
SeRemoteShutdownPrivilegeset to*S-1-5-32-544 (Administrators).
- Policy Display Name:
Rationale
The SeRemoteShutdownPrivilege allows a user authenticating over the network to invoke remote system shutdown and reboot APIs (such as InitiateSystemShutdownEx or shutdown.exe /m \\computer). This function is exposed over named pipe \PIPE\InitShutdown and RPC interface winreg/shutdown.
1. Technical Threat Vector & Abuse Mechanics
Adversaries who obtain credentials possessing SeRemoteShutdownPrivilege can cause widespread operational destruction: (1) Distributed Denial of Service (DDoS): An attacker can trigger mass reboots across workstations, servers, and Domain Controllers, shutting down enterprise business operations; (2) Triggering Malicious Payloads: Forcing an immediate reboot can activate installed kernel drivers, execute pending bootkit configurations, or force users to re-authenticate, exposing plaintext credentials to keystroke loggers; (3) Disrupting Incident Response: Attackers reboot systems to disrupt active volatile memory analysis and terminate forensic collection agents.
2. Architectural Defense & Least Privilege Enforcement
On general workstations and member servers, enforcing least privilege for this user right is critical for host isolation. Preventing unprivileged users or rogue applications from exercising this right stops local privilege escalation (LPE) and blocks adversaries from leveraging co-located user sessions to harvest credentials or pivot across the corporate subnet.
This privilege must be restricted exclusively to Administrators (S-1-5-32-544). Standard domain users, guest accounts, and service accounts must never possess remote shutdown authority.
3. MITRE ATT&CK Mapping
- T1529 - System Shutdown/Reboot
- T1499 - Endpoint Denial of Service
Legacy Impact & Compatibility
- Operational Impact: Restricting
SeRemoteShutdownPrivilegetoAdministratorsprevents unauthorized remote reboot attacks. Centralized systems management platforms (e.g., MECM, Intune, Tanium) running under administrative service contexts continue to manage reboot schedules without issue. Remote shutdown events are logged under System Event ID 1074 and Security Event ID 4672.
Implementation Steps
Option A: Group Policy Object (GPO) Configuration (Preferred)
- Open the Group Policy Management Console (
gpmc.msc). - Navigate to the targeted GPO linked to Tier 2 systems (e.g.,
GPO_Hardening_Endpoints). - In the console tree, browse to:
Computer Configuration\Policies\Windows Settings\Security Settings\Local Policies\User Rights Assignment - Open the policy
Force shutdown from a remote system. - Select the Define these policy settings check box.
- Configure the security principal allocation to:
*S-1-5-32-544 (Administrators). - Click Apply and OK.
- Apply and verify policy enforcement across target hosts using
gpupdate /forceand inspect withsecedit /export /cfg C:\Windows\Temp\sec_audit.cfg.
Option B: PowerShell & Registry Configuration (Remediation / Non-GPO)
Download Script: Configure-UraSeRemoteShutdownPrivilege.ps1
# Configure-UraSeRemoteShutdownPrivilege.ps1
$SecTempDir = Join-Path $env:TEMP "SecurityTemplates"
if (-not (Test-Path $SecTempDir)) { New-Item -Path $SecTempDir -ItemType Directory -Force | Out-Null }
$CfgFile = Join-Path $SecTempDir "ura_seremoteshutdownprivilege.cfg"
$DbFile = Join-Path $SecTempDir "secedit_seremoteshutdownprivilege.sdb"
$LogFile = Join-Path $SecTempDir "secedit.log"
$Process = Start-Process secedit -ArgumentList "/export /cfg `"$CfgFile`"" -Wait -NoNewWindow -PassThru
if ($Process.ExitCode -ne 0) { Throw "Failed to export security template" }
$ConfigText = Get-Content -Path $CfgFile -Raw
if ($ConfigText -notmatch "\[Privilege Rights\]") {
$ConfigText += "`r`n[Privilege Rights]`r`n"
}
$Lines = $ConfigText -split "`r?`n"
$NewLines = @()
$InPriv = $false
$KeyAdded = $false
foreach ($Line in $Lines) {
if ($Line -match "^\[(.*)\]$") {
if ($Matches[1] -eq "Privilege Rights") {
$InPriv = $true
} else {
$InPriv = $false
}
}
if ($InPriv -and $Line -match "^\s*SeRemoteShutdownPrivilege\s*=") {
$NewLines += "SeRemoteShutdownPrivilege = *S-1-5-32-544"
$KeyAdded = $true
} else {
$NewLines += $Line
}
}
if (-not $KeyAdded) {
# Find Privilege Rights section index and insert it right after
$Idx = $NewLines.IndexOf("[Privilege Rights]")
if ($Idx -ge 0) {
$NewLines.Insert($Idx + 1, "SeRemoteShutdownPrivilege = *S-1-5-32-544")
} else {
$NewLines += "SeRemoteShutdownPrivilege = *S-1-5-32-544"
}
}
$NewLines | Set-Content -Path $CfgFile -Force
$Proc = Start-Process secedit -ArgumentList "/configure /db `"$DbFile`" /cfg `"$CfgFile`" /areas USER_RIGHTS /log `"$LogFile`"" -Wait -NoNewWindow -PassThru
if ($Proc.ExitCode -ne 0) { Throw "Failed to configure secedit user rights" }
Remove-Item -Path $CfgFile, $DbFile -ErrorAction SilentlyContinue
To audit the hardening status: Download Script: Get-UraSeRemoteShutdownPrivilegeStatus.ps1
# Get-UraSeRemoteShutdownPrivilegeStatus.ps1
$SecTempDir = Join-Path $env:TEMP "SecurityTemplates"
if (-not (Test-Path $SecTempDir)) { New-Item -Path $SecTempDir -ItemType Directory -Force | Out-Null }
$CfgFile = Join-Path $SecTempDir "ura_audit_seremoteshutdownprivilege.cfg"
$Process = Start-Process secedit -ArgumentList "/export /cfg `"$CfgFile`"" -Wait -NoNewWindow -PassThru
if ($Process.ExitCode -ne 0) {
Write-Output "Non-Compliant"
exit 1
}
$ConfigText = Get-Content -Path $CfgFile -Raw
Remove-Item -Path $CfgFile -ErrorAction SilentlyContinue
$Match = $ConfigText -match "(?mi)^\s*SeRemoteShutdownPrivilege\s*=\s*(.*)$"
$CurrentValue = ""
if ($Match) {
$CurrentValue = $Matches[1].Trim()
}
$Expected = "*S-1-5-32-544"
if ($CurrentValue -eq $Expected) {
Write-Output "Compliant"
exit 0
} else {
Write-Output "Non-Compliant"
exit 1
}
Sources & Compliance References
- ANSSI Active Directory Hardening Guide: ANSSI Active Directory Hardening Guide: R28 (User Rights Assignment)
- CIS Benchmark: 2.2.23 (L1) Ensure 'Force shutdown from a remote system' is set to 'Administrators'
- Microsoft Security Baseline: User Rights Configuration specifications
- Microsoft Learn: User Rights Assignment Reference